10 to 12 SEER 3 to 5 TonsHB3600VC1M25 HB4200VA1M25 Installation & Operation Manual Air Handler HB6000VA1M25 HB6000VC1M25 HB4800VA1M25W
THERMOSTAT WIRING10For Thermostat Control Environment-temperature and Air Conditioning open/stop, the wiringdiagram as shown diagram 1. Thermostat can
11For Thermostat Control Environment-temperature and Air Conditioning open/stop, the wiringdiagram as shown diagram 4. Thermostat can be mechanical ty
SEAL CAP13/16 NUTTAIL PIECEWHITE TEFLON SEALPISTONSUCTION LINEWITH SPINCLOSURERUBBERGROMMETORIFICE CHANGEThe restrictor (orifice) included in this un
BLOWER PERFORMANCECFM versus Static Pressure (inches of water column dry coil w/ filter) 4% reduction for wet coil.The air delivery can be varied by c
START-UPPrior to initial start-up insure that all electrical connections are properly sized and tightened.All panels must be in place and secured.Tubi
INDEXTOPIC PAGEGeneralPhysical dimensionsReplacement Parts SourceInstallation RequirementsAir Flow OrientationHorizontal Left-Hand InstructionsDownflo
DCPRIMARY & SECONDARYCONDENSATE DRAINS-HORIZONTAL 3/4" NPT 2"[5.08 cm] 5.1"[13 cm] 2"[5.08 cm]TYPICALFKG 1.1"
REPLACEMENT PARTS SOURCEReplacement parts are available through local distributors.When ordering replacement parts, givethe COMPLETE model and seria
AIR FLOW ORIENTATIONDownflow discharge(with plastic verticalpan only) (see page 7)*Horizontal Right Discharge Tube and Drain conn. frontHorizontal
HORIZONTAL LEFT-HAND INSTRUCTIONSImportant: Read instructions below carefully.1) With Airhandler in the vertical position, remove all three access
DOWNFLOW INSTRUCTIONSImportant: Read instructions below carefully1.Before putting the Air Handler in the downflow position, remove the three access p
REFRIGERANT TUBINGCONDENSATE REMOVALRefrigerant tubing should be installed as to avoid undue stress. They must be supported orrouted to avoid strain o
ELECTRICAL CONNECTIONSThe required electrical power supply information is located on the series and rating plateon the exterior of the unit. Wiring se