No.0010572324
K
10 to 13 SEER 1.5 to 5 Tons
Models: HC18-60A1VAR/S
HC18-60C1VAR
HC18-60D1VAR
Installation & Operation Manual
Central Air Conditioner
The information contained in this booklet is subject to change without notice.
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - Central Air Conditioner

No.0010572324 K 10 to 13 SEER 1.5 to 5 Tons Models: HC18-60A1VAR/S HC18-60C1VAR

Page 2 - ! WARNING

The factory charge is sufficient for 25 feet of standard liquid line. For longer or shorter liquid linelengths, adjust the charge as follows:1/4"

Page 3 - TABLE OF CONTENT

91.Tubing should be cut square. Make sure it is round and free of burrs at the connecting ends. Clean the tubing to prevent contamination from ente

Page 4 - 3.SPECIFICATION

1.Fully open both shutoff valves.2.Connect service gage manifold to the valve service ports, being sure to evacuate lines.3.Startup the system (Ref

Page 5 - Figure 1

11The condensing unit rating plate and the tables of "Physical and Electrical Specifications / OutdoorUnits" (Table 1 and 2) provide pertine

Page 6 - Table 5:

128.OPERATIONMost single phase units are operated without start relay or start capacitor. Such systems shouldbe off for a minimum of 5 minutes before

Page 7 - 6.INSTALLATION

13 Run or start capacitor defective Replace Loose connection

Page 8

5PUELECTRIC HEATER KITRDBLAir Conditioner Wi ring Diagram1) Confi rm system selection. Optional com ponents m ay be field or factory installed.2) If

Page 9

Made in P.R.C.

Page 10

! WARNINGThese instructions are intended as an aid to qualified, licensed service personnel for proper installation,adjustment and operation of this u

Page 11

1TABLE OF CONTENT1.Introduction ---------------------------------------------------------------------------------------2.Nomenclature for Model Number

Page 12 - 6.4.ELECTRICAL WIRING

23.SPECIFICATIONThe dimensions for the condensing unit are illustrated in Figure 1. Physical and electricalspecifications are provided in Table 1 for

Page 13 - 7.SYSTEM STARTUP

Figure 1Minimum Circuit Amps 15 25 25

Page 14 - 9.MISCELLANEOUS

4Outdoor Unit With This Indoor Air handlerModel NumberHC18C1VAR HB2400VC1M20HC24C1VAR HB

Page 15

54.UNIT INSPECTIONThis product has been inspected at the factory and released to the transportation agency withoutknown damage. Inspect exterior of ca

Page 16 - HC18-60D1VAR

Provide a level concrete slab. To prevent transmission of noise or vibration, slab should not be connectedto building structure. Some sort of sound-ab

Page 17 - Made in P.R.C

OUTDOOR UNITLIQUID LINEPITCH SUCTION LINE TOWARD OUTDOORUNIT 1/2" FRO EVERY 10' OF LINEINDOOR UNIT ABOVE ORLEVEL TO OUTDOOR UNITINDOOR UNITO