Prepare Window for Installation
Attach Adhesive Seal
1. Cut the adhesive seal to the width of the lower window sash.
2. Remove the backing from the seal and attach the seal to the
bottom of the lower window sash.
Install L Brackets
1. Measure the width of the window opening and mark the
center line on the outside windowsill.
2. Use ¹⁄₈" drill bit to drill a starter hole for each of the two L
brackets located 7¹⁄" from the center line.
3. Using ³⁄₄" screws, install the L brackets on the outside
windowsill. The short side of the brackets should face toward
the outside.
Position the Air Conditioner
NOTES:
Handle air conditioner gently.
Be sure your air conditioner does not fall out of the opening
during installation or removal.
The place where the power cord exits the air conditioner
should be:
- Heat/Cool Models - no more than 4 ft (122 cm) from a
Do not block the louvers in the front panel.
Do not block the louvers on the outside of the air conditioner.
1. Center air conditioner in window. Be sure the bottom
channels on the air conditioner drop into the notches of the L
brackets. Lower the window sash behind the top channel to
hold cabinet in place.
NOTE: Your model may differ from the one shown.
A. Width of window opening
B. Center line
B
A
A. Outside windowsill
B.
³⁄₄
" screw
C. Inside windowsill
D. Center line
E. 7
¹⁄₂
"
F. Short side of L bracket
A
B
C
D
B
E
E
F
WARNING
Excessive Weight Hazard
Use two or more people to move and install
air conditioner.
Failure to do so can result in back or other injury.
A. Side curtain against window channel
B. Window sash behind top channel
C. Bottom channel in bracket notches
B
C
A
grounded outlet.
- Cool Only Models - no more than 6 ft (182.9 cm) from a
grounded outlet.
IF AC IS BLOCKED BY STORM WINDOW
Add wood as shown in FIG.6, or remove storm window
frame before air conditioner is installed.
If storm window frame must remain, be sure the drain
holes or slots are not caulked or painted shut.
Accumulated rain water or condensation must be allowed
to drain out.