Outdoor unit
1.Installation of Outdoor Unit
3.Connection
4.Atta
ching Drain-Elbow
2.Connection of pipes
Install according to
To bend a pipe, give the roundness as large as possible not to crush the pipe
Connecting the pipe of gas side first makes working easier.
The max vertical distance between the indoor unit and the outdoor unit is 5 m.
Use the same method on indoor unit
. Loosen the screws on terminal block and insert the plugs fully into
te
rminal block, then tighten the screws.
If wi
ring is not correct, proper operation can not be carried out and controller may be damaged.
If the drain-elbow is used, please attach it as
figure. (Note: Only for heat pump unit.)
Dr
awing for the installation of indoor and outdoor units
Inse
rt the cable according to terminal number in the same manner as the indoor unit.
Fix the ca
ble with a clamp.
Half union
Flare nut
Spanner
Torque wrench
6
Outdoor unit
Forced fastening without careful centering
may damage the threads and cause a
leakage of ga
s.
Be careful that matters, such as wastes of sands, etc. shall not enter the pipe.
Pipe Diameter ( )
Liquid side 6.35mm(1/4")
Gas side 9.52mm(3/8")
Fastening torque
18N.m
42N.m
Gas side 12.7mm(1/2")
50N.m