Page view 161
>a__WcU[S^ <[c >a`V[e[a`Wc
B:BLACK
NOTE˖1ǃ
REMOTE CONTROLLER IS OPTIONAL .
2ǃREFER TO OPERATION INDOOR MANUL TO SET DIP BM1-BM4 .
PLEASE DO NOT CHANGE THE DIP SWITCH RANDOM.
3ǃNO ELECTRIC HEATING TYPE WITHOUT ELECTRIC HEATER.
R:RED
BL:BLUE
W:WHITE
Y/G:YELLOW/GREEN
2
1
3
CN13
CN12
CN11
CN22
CN2
SWING MOTOR
CONTROL PANEL
ROOM TEMP. SENSOR
PIPING TEMP. SENSOR
SWING
MOTOR
REMOTE CONTROLLER
Y/G
Y/G
FAN MOTOR
HEATER
TO OUTDOOR UNIT
W
ONE-OFF FUSE
RESUMABLE PROTECTOR
B
R
CAPACITOR
FUSE
M
M
BYBLR
T3.15A/250VAC
CN23
CN3
BM2
BM1
CN4CN24
CN25
CN10
BM4
BM3
CN7
CN5
CN6
TRANSFORMER
CIRCUIT DIAGRAM OF INDOOR UNIT
M
0010578100
AP482AKEAA
BM1 Funcion selection
BM1-1 ON/OFF cooling only / heat pump
BM1-2 ON/OFF Automatic run A / B mode
BM2 and BM3: used for indoor unit to set unit address from 1 to 128’
BM4 Panel selection Select the panel according to the 2 dip switch
Style of panel 1 2
Cabinet V panel OFF ON
Cabinet Z panel ON OFF
Wired controller ON ON